No.333 Hezuo Road, Hi-Tech Zone, Chengdu 611731 CN
Home ProductsPoint Of Care Analyzer

High Accuracy Point Of Care Analyzer Full Auto Testing Equipment For Human

High Accuracy Point Of Care Analyzer Full Auto Testing Equipment For Human

    • small.img.alt
    • small.img.alt
  • large.img.alt

    Product Details:

    Place of Origin: Chengdu, China
    Brand Name: Seamaty
    Certification: CE , ISO13458 , FSC , ect.
    Model Number: SD1

    Payment & Shipping Terms:

    Minimum Order Quantity: 1 unit
    Price: Negotiable
    Packaging Details: 315*375*475 mm CARTON
    Delivery Time: Within 3-5 working days upon receipt of payment
    Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability: 150-200 sets a month
    Contact Now
    Detailed Product Description
    Product Name: SD1 Sample Type: Lithium Heparin Anti-coagulant Whole Blood, Serum And Plasma
    Sample Volume: 100ul Testing Time: 12 Minutes / Smaple
    Printer: Built-in Thermal Printer QC&Calibrate: IQC Intelligent QC
    High Light:

    point of care hematology analyzer

    ,

    point of care testing devices

     

    High Accuracy Point of Care Analyzer for Human / Full Auto Chemistry Analyzer

     

     

    Advantages:

     

    1 Little Sample Volume Required

    Sample volume needed is 1/10-1/20 of traditional chemistry analyzer.

     

    2 Easy to Carry

    4.2 Kg. The protable analyzer is designed to save space, use it anywhere anytime.

     

    3 Less Maintenance

    No consumables needed such as tubes, pump, value etc, saving your maintenance expenese.

     

    4 Accurate Result

    Using the photoelectric colormetric principle, the SD1 analyzer has many advantages versus traditional dry biochemistry analyzer using the light reflection method. Dilution of test sample is guaranteed without random errors and cross contaminations.

     

     

    Product Introduction:

     

    High Accuracy Point Of Care Analyzer Full Auto Testing Equipment For Human

     

     

     

     

     

     

     

     

     

     

    Immediate Results Anywhere Anytime  

     

    Optional Accessories:

    High Accuracy Point Of Care Analyzer Full Auto Testing Equipment For Human

     

     

     

    Operation Steps:

     

    All steps are full-automated from centrifugation, dulition, quality control to test result printing.

     

    1. Insert Sample (100ul)

    No sample pretreatment needed.

    Only l00ul of whole blood / serum / plasma needed.

     

    2. Insert Reagent Disc (12 minutes testing time)

    Maintenance free and easy to use in a field or mobile setting. Key parts imported from USA.

    Internal centrifugation of test sample. No internal liquids or pumps.

     

    3. Interpret result (immediately)

    Reads results using the photoelectric colorimetric principle.

    No random error or cross infection possible. Automatically prints result.

     

    Specification:

     

    Sample Type Lithium Heparin Anti-coagulant whole blood, serum or plasma
    Sample Volume 100 ul
    Bar Code QR code
    Testing Time 12 minutes / sample
    Testing Principle Absorption spectroscopy, transmission turdimetry
    Testing Method End point, kinetic, fixed time, turbidimetry
    Temperature 37℃ ± 0.3℃
    QC & Calibrate IQC intelligent QC
    Storage 500,000 results
    Printer Built-in thermal printer
    Connectors 4 USB ports, 1 LAN port
    Weight 4.2 Kg of the analyzer, 0.6 Kg of power adapter
    Size 315*375*475 mm

     

    FAQ

     

    1. Can expired disc be used in the SD1 ?

    No. The analyzer has a built-in sensor for determine if the disc has expired.If the disc is beyond the expiration date, the analyzer will cancel the run and display a code error message.

     

    2. What is the shelf life of the test reagent disc?

    The shelf life of a test reogent disc is 12 months (see package for expiration dote).

    Seamaty recommends that disc should be stored and rofrigeratod at 2-8° C (3A-46° F).

    Discs stored above 8° C will degrade faster throughout their shelf life.

     

    3. Do discs require warm-up time before use?

    Yes. We recommend that disc be used after 20 minutes warming up when it is taken out of refrigerator for optimal performance.

     

    4. Can the discs be reused?

    No. The discs are single-use, one disc is for one patient. They are considered a bio-hazard and should be disposed of in proper containers.

     

    5. What types of samples can be used with the SD1?

    Lithium-heparin whole blood, lithium-heparin plasma, or serum, do not use EDTA as an anti-coagulant.

     

    6. What is the proper fubes for blood sample collection?

    Seamaty offers enough FOC tubes (lithium heparin), pipette and pipette tips after your reagent disc order. Do not use EDTA tube.

     

     

     

     

     

     

    Contact Details
    Chengdu Seamaty Technology Co.,Ltd

    Contact Person: sales11

    Send your inquiry directly to us (0 / 3000)

    Other Products
    Request A Quote

    E-Mail | Sitemap

    Privacy Policy China Good Quality Veterinary Chemistry Analyzer Supplier. © 2019 - 2022 veterinarychemistryanalyzer.com. All Rights Reserved.